The report summarises the results of the EURAMET.T-K8 key comparison (EURAMET Project No. P 717) in the field of humidity. The comparison covers the dew-point temperature range from +30 °C up to + 95 °C dew point temperature. The report gives details of the scheme, procedure and analysis of the comparison. The overall results display a very good agreement of the 16 participating laboratories. The two dew-point hygrometers used as travelling standard were sufficiently stable. The linkage to the corresponding CCT-K8 comparison will be calculated when the final results for both comparisons are available. Possible procedures are described in the text. In the conclusion, some remarks for improvement for future RMO key comparisons are given. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Comparison in humidity (dew-point temperature high range) dew point temperature +30 °C to 95 °C / Deschermeier, Regina; Bell, Stephanie; Benyon Puig, Robert; Bonde Kentved, Anders; Carroll, Paul; Fernicola, Vito; García Gallegos, Jamie; Heinonen, Martti; Hudolkin, Domen; Jarosz, Rafał; Kokkini, Evmorfia; Mac Lochlainn, Dubhaltach; Mitter, Helmut; Oğuz Aytekin, Seda; Panman, Matthijs; Senn, Remo; Šestan, Danijel; Smorgon, Denis; Stevens, Mark; Zvizdić, Davor. - In: METROLOGIA. - ISSN 0026-1394. - 61:1A(2024). [10.1088/0026-1394/61/1a/03008]

Comparison in humidity (dew-point temperature high range) dew point temperature +30 °C to 95 °C

Fernicola, Vito;Smorgon, Denis
Investigation
;
2024

Abstract

The report summarises the results of the EURAMET.T-K8 key comparison (EURAMET Project No. P 717) in the field of humidity. The comparison covers the dew-point temperature range from +30 °C up to + 95 °C dew point temperature. The report gives details of the scheme, procedure and analysis of the comparison. The overall results display a very good agreement of the 16 participating laboratories. The two dew-point hygrometers used as travelling standard were sufficiently stable. The linkage to the corresponding CCT-K8 comparison will be calculated when the final results for both comparisons are available. Possible procedures are described in the text. In the conclusion, some remarks for improvement for future RMO key comparisons are given. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/85800
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact