A methodology for the Bayesian evaluation of total specific risks of false decisions on conformity of a substance or material due to measurement uncertainty was developed using Monte Carlo simulations, taking into account the mass balance constraint of the data. As a case study, the measurement results (measured values and associated measurement uncertainty) obtained for testing a potassium iodate batch, being considered as a candidate reference material of potassium iodate purity, were analyzed and discussed for different models of the prior probability density function and the likelihood function. Different scenarios of the risks related to determination of potassium iodate purity were studied, when the direct or indirect test method is applied, as well as when both are used simultaneously.
Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint – A case study of potassium iodate / Pennecchi, Francesca R.; Kuselman, Ilya; Di Rocco, Aglaia; Brynn Hibbert, D.; Sobina, Alena; Sobina, Egor. - In: MEASUREMENT. - ISSN 0263-2241. - 173:(2021), p. 108662. [10.1016/j.measurement.2020.108662]
Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint – A case study of potassium iodate
Pennecchi, Francesca R.;
2021
Abstract
A methodology for the Bayesian evaluation of total specific risks of false decisions on conformity of a substance or material due to measurement uncertainty was developed using Monte Carlo simulations, taking into account the mass balance constraint of the data. As a case study, the measurement results (measured values and associated measurement uncertainty) obtained for testing a potassium iodate batch, being considered as a candidate reference material of potassium iodate purity, were analyzed and discussed for different models of the prior probability density function and the likelihood function. Different scenarios of the risks related to determination of potassium iodate purity were studied, when the direct or indirect test method is applied, as well as when both are used simultaneously.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0263224120311751-main.pdf
non disponibili
Descrizione: Articolo principale
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.68 MB
Formato
Adobe PDF
|
1.68 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
MEAS-S-20-04601_29.07.20.pdf
accesso aperto
Tipologia:
submitted version (author’s pre-print)
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
4.14 MB
Formato
Adobe PDF
|
4.14 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.