Specific loss power has been measured on γ-Fe2O3 nanoparticles dispersed in water by means of several tech- niques, i.e. heat flow in a calorimeter, hyperthermia, and static and dynamic hysteresis loops. Static hysteresis loops as a function of the maximum applied field underestimate the power losses as dynamic effects are not exploited, but turned out to be a valuable tool to prove the consistency of specific loss power measurements obtained by the other techniques over a wide range of applied magnetic field intensities. A temperature-de- pendence of the specific loss power has been taken into account in hyperthermia measurements performed with a fully modelled non adiabatic experimental setup. Simple mean-field theoretical models (interacting super- paramagnetic, modified Stoner-Wohlfarth) have been exploited to reproduce the static energy losses of the particles.
Specific loss power measurements by calorimetric and thermal methods on T γ-Fe2O3 nanoparticles for magnetic hyperthermia / Coisson, Marco; Barrera, Gabriele; Appino, Carlo; Celegato, Federica; Martino, LUCA UGO; Safronov, Alexander P.; Kurlyandskaya, Galina V.; Tiberto, PAOLA MARIA. - In: JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS. - ISSN 0304-8853. - 473:(2019), pp. 403-409. [10.1016/j.jmmm.2018.10.107]
Specific loss power measurements by calorimetric and thermal methods on T γ-Fe2O3 nanoparticles for magnetic hyperthermia
Marco Coïsson
;Gabriele Barrera;Carlo Appino;Federica Celegato;Luca Martino;Paola Tiberto
2019
Abstract
Specific loss power has been measured on γ-Fe2O3 nanoparticles dispersed in water by means of several tech- niques, i.e. heat flow in a calorimeter, hyperthermia, and static and dynamic hysteresis loops. Static hysteresis loops as a function of the maximum applied field underestimate the power losses as dynamic effects are not exploited, but turned out to be a valuable tool to prove the consistency of specific loss power measurements obtained by the other techniques over a wide range of applied magnetic field intensities. A temperature-de- pendence of the specific loss power has been taken into account in hyperthermia measurements performed with a fully modelled non adiabatic experimental setup. Simple mean-field theoretical models (interacting super- paramagnetic, modified Stoner-Wohlfarth) have been exploited to reproduce the static energy losses of the particles.File | Dimensione | Formato | |
---|---|---|---|
a) 2019 CoiBarAppCelMarSafKurTib JMMM.pdf
solo utenti autorizzati
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
908.88 kB
Formato
Adobe PDF
|
908.88 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.