An accurate measurement of saturation vapor pressure of supercooled water is a strong challenge in metrology, mainly due to difficulties concerning keeping water at a liquid state at temperatures well below the melting point; thus few experimental data covering limited temperature ranges (down to about 253 K) are reported in literature. For this reason, an investigation of the water vapor – supercooled water equilibrium along the saturation line is carried out at Istituto Nazionale di Ricerca Metrologica (INRIM). Measurements cover the temperature range from 261.26 K to 273.25 K, corresponding to a saturation vapor pressure from about 244 Pa to 611 Pa. The experimental apparatus includes a borosilicate glass sample cell, kept in a liquid bath at a constant temperature with millikelvin stability and connected to a manifold where the pressure is measured using a capacitive diaphragm pressure gauge. In this work, the water sample preparation, the measuring method and measurement corrections are reported; moreover, a comparison between experimental and literature data is conducted along with the most used vapor pressure formulations. Measurement results are discussed and uncertainty sources estimated. The resulting expanded relative uncertainty (k = 2) varies from 0.085% at 261.26 K to 0.039% at 273.25 K.
Vapor pressure measurements over supercooled water in the temperature range from −10 1 °C to +10 −2 °C / Beltramino, G.; Rosso, L.; Smorgon, D.; Fernicola, V.. - In: JOURNAL OF CHEMICAL THERMODYNAMICS. - ISSN 0021-9614. - 105:(2017), pp. 159-164. [10.1016/j.jct.2016.10.003]
Vapor pressure measurements over supercooled water in the temperature range from −10 1 °C to +10 −2 °C
Beltramino, G.
;Rosso, L.;Smorgon, D.;Fernicola, V.
2017
Abstract
An accurate measurement of saturation vapor pressure of supercooled water is a strong challenge in metrology, mainly due to difficulties concerning keeping water at a liquid state at temperatures well below the melting point; thus few experimental data covering limited temperature ranges (down to about 253 K) are reported in literature. For this reason, an investigation of the water vapor – supercooled water equilibrium along the saturation line is carried out at Istituto Nazionale di Ricerca Metrologica (INRIM). Measurements cover the temperature range from 261.26 K to 273.25 K, corresponding to a saturation vapor pressure from about 244 Pa to 611 Pa. The experimental apparatus includes a borosilicate glass sample cell, kept in a liquid bath at a constant temperature with millikelvin stability and connected to a manifold where the pressure is measured using a capacitive diaphragm pressure gauge. In this work, the water sample preparation, the measuring method and measurement corrections are reported; moreover, a comparison between experimental and literature data is conducted along with the most used vapor pressure formulations. Measurement results are discussed and uncertainty sources estimated. The resulting expanded relative uncertainty (k = 2) varies from 0.085% at 261.26 K to 0.039% at 273.25 K.File | Dimensione | Formato | |
---|---|---|---|
Paper_water vapor measurements over supercooled water_clean.pdf
accesso aperto
Tipologia:
accepted manuscript (author’s post-print)
Licenza:
Creative Commons
Dimensione
354.81 kB
Formato
Adobe PDF
|
354.81 kB | Adobe PDF | Visualizza/Apri |
1-s2.0-S0021961416303032-main.pdf
non disponibili
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
657.85 kB
Formato
Adobe PDF
|
657.85 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.