BERGOGLIO, MERCEDE
BERGOGLIO, MERCEDE
Non assegnato
An investigation of quartz type pressure transducer behavior under continuous pressure conditions and metrological characterization
2012 By:kocas, I; Bergoglio, Mercede
Analysis of interlaboratory comparisons affected by correlations of the reference standards and drift of the travelling standards
2011 Bergoglio, Mercede; Malengo, Andrea; Mari, DOMENICO GIANLUCA
Calculation of effective area A(0) for six piston-cylinder assemblies of pressure balances. Results of the EUROMET Project 740
2005 Molinar, G; Bergoglio, Mercede; Sabuga, W; Otal, P; Ayyildiz, G; Verbeek, J; Farar, P.
CCM comparison CCM.M.P-K14 for absolute pressures in the range from 100 μPa to 1 Pa
2011 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
Determinazione dei rapporti di espansione dell'impianto ad espansione statica
2009 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
Dynamic vacuum measurement by an optical interferometric technique
2014 Mari, DOMENICO GIANLUCA; Bergoglio, Mercede; Pisani, Marco; Zucco, Massimo
EURAMET 1047. EURAMET Key comparison of National Standards in the range from 1 Pa to 15kPa in gauge mode
2011 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; DE MARIA, Paolo
EURAMET 1125. Evaluation of cross-float measurements with pressure balances
2011 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
Evaluation of the conductance of the I.N.RI.M. continuous expansion system D2
2008 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
Experimental and computational study of gas flow delivered by a rectangular microchannels leak
2015 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; Chen, J; Si Hadj Mohand, H; Colin, S; Barrot, C.
Final Report on Key Comparison CCM.P-K7 in the range 10 MPa to 100 MPa of hydraulic gauge pressure
2005 W., Sabuga; Bergoglio, Mercede; T., Rabault; B., Waller; J. C., Torres; D. A., Olson; A., Agarwal; T., Kobata; A. K., Bandyopadhyay
Flussometro primario per la misura di piccole portate di gas con riferimento alla pressione atmosferica
2009 Bergoglio, M.; Maghenzani, R.; Mari, D
Gas flow measurements performed at INRIM Istituto Nazionale di Ricerca Metrologica - Torino- Italy
2010 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; Streito, S.
INRIM continuous expansion system as high vacuum primary standard for gas pressure measurements below 9 x 10(-2) Pa
2009 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
INRIM primary standard for microgas-flow measurements with reference to atmospheric pressure
2012 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
INRIM results for CCM key comparison CCM.P-K-12 for He leak rates
2007 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
INRIM results for EURAMET.M.P-S7 1040 comparison in gas media (absolute mode) from 100 µPa to 1 Pa
2010 Bergoglio, Mercede; Mari, DOMENICO GIANLUCA
Intercomparison of gas flow-rate measurements at IMGC, Italy, and UASG, Germany, in the range from 10(-8) to 10(-3) Pa m(3)/s
2005 Bergoglio, Mercede; Raiteri, G; Rumiano, G; Jitschin, W.
La taratura dei leak detector a elio
2005 Bergoglio, Mercede; Calcatelli, A.
Leak detection, calibrations and reference flows: Practical example
2007 Mari, DOMENICO GIANLUCA; Bergoglio, Mercede; Calcatelli, A.
Citazione | Data di pubblicazione | Autori | File |
---|---|---|---|
An investigation of quartz type pressure transducer behavior under continuous pressure conditions and metrological characterization / By:kocas, I; Bergoglio, Mercede. - In: MEASUREMENT. - ISSN 0263-2241. - 45:10(2012), pp. 2486-2489. [10.1016/j.measurement.2011.10.038] | 2012 | BERGOGLIO, MERCEDE + | - |
Analysis of interlaboratory comparisons affected by correlations of the reference standards and drift of the travelling standards / Bergoglio, Mercede; Malengo, Andrea; Mari, DOMENICO GIANLUCA. - In: MEASUREMENT. - ISSN 0263-2241. - 44:8(2011), pp. 1461-1467. [10.1016/j.measurement.2011.05.012] | 2011 | BERGOGLIO, MERCEDEMALENGO, ANDREAMARI, DOMENICO GIANLUCA | - |
Calculation of effective area A(0) for six piston-cylinder assemblies of pressure balances. Results of the EUROMET Project 740 / Molinar, G; Bergoglio, Mercede; Sabuga, W; Otal, P; Ayyildiz, G; Verbeek, J; Farar, P.. - In: METROLOGIA. - ISSN 0026-1394. - 42:(2005), pp. S197-S201. [10.1088/0026-1394/42/6/S11] | 2005 | BERGOGLIO, MERCEDE + | - |
CCM comparison CCM.M.P-K14 for absolute pressures in the range from 100 μPa to 1 Pa / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2011). | 2011 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
Determinazione dei rapporti di espansione dell'impianto ad espansione statica / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2009). | 2009 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
Dynamic vacuum measurement by an optical interferometric technique / Mari, DOMENICO GIANLUCA; Bergoglio, Mercede; Pisani, Marco; Zucco, Massimo. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 25:(2014). [10.1088/0957-0233/25/12/125303] | 2014 | MARI, DOMENICO GIANLUCABERGOGLIO, MERCEDEPISANI, MARCOZUCCO, MASSIMO | - |
EURAMET 1047. EURAMET Key comparison of National Standards in the range from 1 Pa to 15kPa in gauge mode / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; DE MARIA, Paolo. - (2011). | 2011 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCADE MARIA, PAOLO | - |
EURAMET 1125. Evaluation of cross-float measurements with pressure balances / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2011). | 2011 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
Evaluation of the conductance of the I.N.RI.M. continuous expansion system D2 / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2008). | 2008 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
Experimental and computational study of gas flow delivered by a rectangular microchannels leak / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; Chen, J; Si Hadj Mohand, H; Colin, S; Barrot, C.. - In: MEASUREMENT. - ISSN 0263-2241. - 73:(2015), pp. 551-562. [10.1016/j.measurement.2015.06.011] | 2015 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA + | PAPER_rectangular-micro-device.pdf; PAPER_rect_microchannels-leak_2015_POST-PRINT.pdf |
Final Report on Key Comparison CCM.P-K7 in the range 10 MPa to 100 MPa of hydraulic gauge pressure / W., Sabuga; Bergoglio, Mercede; T., Rabault; B., Waller; J. C., Torres; D. A., Olson; A., Agarwal; T., Kobata; A. K., Bandyopadhyay. - In: METROLOGIA. - ISSN 1681-7575. - 42:(2005), p. 07005. [10.1088/0026-1394/42/1A/07005] | 2005 | BERGOGLIO, MERCEDE + | - |
Flussometro primario per la misura di piccole portate di gas con riferimento alla pressione atmosferica / Bergoglio, M.; Maghenzani, R.; Mari, D. - (2009). (Intervento presentato al convegno 6° Congresso metrologia & qualità). | 2009 | Bergoglio, M.Mari, D + | - |
Gas flow measurements performed at INRIM Istituto Nazionale di Ricerca Metrologica - Torino- Italy / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA; Streito, S.. - (2010). | 2010 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA + | - |
INRIM continuous expansion system as high vacuum primary standard for gas pressure measurements below 9 x 10(-2) Pa / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - In: VACUUM. - ISSN 0042-207X. - 84:1(2009), pp. 270-273. [10.1016/j.vacuum.2009.04.002] | 2009 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
INRIM primary standard for microgas-flow measurements with reference to atmospheric pressure / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - In: MEASUREMENT. - ISSN 0263-2241. - 45:(2012), pp. 2459-2463. [10.1016/j.measurement.2011.10.039] | 2012 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
INRIM results for CCM key comparison CCM.P-K-12 for He leak rates / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2007). | 2007 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
INRIM results for EURAMET.M.P-S7 1040 comparison in gas media (absolute mode) from 100 µPa to 1 Pa / Bergoglio, Mercede; Mari, DOMENICO GIANLUCA. - (2010). | 2010 | BERGOGLIO, MERCEDEMARI, DOMENICO GIANLUCA | - |
Intercomparison of gas flow-rate measurements at IMGC, Italy, and UASG, Germany, in the range from 10(-8) to 10(-3) Pa m(3)/s / Bergoglio, Mercede; Raiteri, G; Rumiano, G; Jitschin, W.. - In: VACUUM. - ISSN 0042-207X. - 80:(2005), pp. 561-567. | 2005 | BERGOGLIO, MERCEDE + | - |
La taratura dei leak detector a elio / Bergoglio, Mercede; Calcatelli, A.. - (2005). (Intervento presentato al convegno Conferenza Nazionale sulle Prove non distruttive Monitoraggio Diagnostica tenutosi a Milano nel 13-15 ottobre 2005). | 2005 | BERGOGLIO, MERCEDE + | - |
Leak detection, calibrations and reference flows: Practical example / Mari, DOMENICO GIANLUCA; Bergoglio, Mercede; Calcatelli, A.. - In: VACUUM. - ISSN 0042-207X. - 81:11-12(2007), pp. 1538-1544. [10.1016/j.vacuum.2007.04.019] | 2007 | MARI, DOMENICO GIANLUCABERGOGLIO, MERCEDE + | - |