A method to characterize instruments based on ILMDs (Image Luminance Measuring Device) for applications in road and tunnel lighting installation is presented. In road lighting applications, these devices measure the road surface luminance for controlling smart adaptive road lighting systems. The measurement range is between 0,1 cd m-2 and 3 cd m-2 (CEN, 2015a). In tunnel lighting, the instrument measures the atmospheric luminance, the equivalent veiling luminance and calculates the veiling luminance for controlling the lighting level in the threshold zone of the tunnel. In this case the range of measured luminances is between 100 cd m-2 and 20 kcd m-2. In both cases instruments should have low cost, a great stability and repeatability, and low sensitivity to climatic conditions (CEN, 2015b). Their calibration procedure shall be simple but adequate to application requirements and real operating conditions.
METROLOGICAL CHARACTERIZATION OF ILMD FOR SMART LIGHTING APPLICATIONS / Rossi, G.; Iacomussi, P.; Radis, M.. - (2017). (Intervento presentato al convegno Smarter Lighting for Better Life tenutosi a JEJU COREA DEL SUD nel 23-25 OTTOBRE 2017).
METROLOGICAL CHARACTERIZATION OF ILMD FOR SMART LIGHTING APPLICATIONS
	
	
	
		
		
		
		
		
	
	
	
	
	
	
	
	
		
		
		
		
		
			
			
			
		
		
		
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
		
		
		
	
Rossi, G.
;Iacomussi, P.
;Radis, M.
			2017
Abstract
A method to characterize instruments based on ILMDs (Image Luminance Measuring Device) for applications in road and tunnel lighting installation is presented. In road lighting applications, these devices measure the road surface luminance for controlling smart adaptive road lighting systems. The measurement range is between 0,1 cd m-2 and 3 cd m-2 (CEN, 2015a). In tunnel lighting, the instrument measures the atmospheric luminance, the equivalent veiling luminance and calculates the veiling luminance for controlling the lighting level in the threshold zone of the tunnel. In this case the range of measured luminances is between 100 cd m-2 and 20 kcd m-2. In both cases instruments should have low cost, a great stability and repeatability, and low sensitivity to climatic conditions (CEN, 2015b). Their calibration procedure shall be simple but adequate to application requirements and real operating conditions.| File | Dimensione | Formato | |
|---|---|---|---|
| METROLOGICAL-CHARACTERIZATION-OF-ILMD-FOR-SMART-LIGHTING-APPLICATIONS.pdf non disponibili 
											Tipologia:
											submitted version (author’s pre-print)
										 
											Licenza:
											
											
												Non Pubblico - Accesso privato/ristretto
												
												
												
											
										 
										Dimensione
										189.23 kB
									 
										Formato
										Adobe PDF
									 | 189.23 kB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.