Calibration by comparison of platinum resistance thermometers and thermocouples requires transfer media capable of providing very good short-term temperature uniformity and temperature stability over a wide temperature range. This paper describes and compares the performance of two potassium-filled gas-controlled heat pipes (GCHP) for operation over the range from 420 ◦C to 900 ◦C. One of the heat pipes has been in operation for more than 10 years having been operated at temperature for thousands of hours, while the other was commissioned in 2010 following recently developed improvements to both the design, assembly, and filling processes. It was found that the two devices, despite differences in age, structure, number of wells, and filling processes, realized the same temperatures within the measurement uncertainty. The results show that the potassium-filled GCHP provides a durable and high-quality transfermedium for performing thermometer calibrations with very low uncertainties, over the difficult high-temperature range from 420 ◦C to 900 ◦C.
Comparison of Two Potassium-Filled Gas-Controlled Heat Pipes / Bertiglia, Fabio; Iacomini, Luigi; Moro, F.; Merlone, Andrea. - In: INTERNATIONAL JOURNAL OF THERMOPHYSICS. - ISSN 0195-928X. - 36:12(2015), pp. 3393-3403. [10.1007/s10765-015-2002-4]
Comparison of Two Potassium-Filled Gas-Controlled Heat Pipes
BERTIGLIA, FABIO
;IACOMINI, LUIGI;MERLONE, ANDREA
2015
Abstract
Calibration by comparison of platinum resistance thermometers and thermocouples requires transfer media capable of providing very good short-term temperature uniformity and temperature stability over a wide temperature range. This paper describes and compares the performance of two potassium-filled gas-controlled heat pipes (GCHP) for operation over the range from 420 ◦C to 900 ◦C. One of the heat pipes has been in operation for more than 10 years having been operated at temperature for thousands of hours, while the other was commissioned in 2010 following recently developed improvements to both the design, assembly, and filling processes. It was found that the two devices, despite differences in age, structure, number of wells, and filling processes, realized the same temperatures within the measurement uncertainty. The results show that the potassium-filled GCHP provides a durable and high-quality transfermedium for performing thermometer calibrations with very low uncertainties, over the difficult high-temperature range from 420 ◦C to 900 ◦C.File | Dimensione | Formato | |
---|---|---|---|
2015_Article_ComparisonOfTwoPotassium-Fille.pdf
non disponibili
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.23 MB
Formato
Adobe PDF
|
1.23 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
PRE PRINT Comparison of Two Potassium-Filled Gas-Controlled Heat Pipes.pdf
accesso aperto
Tipologia:
submitted version (author’s pre-print)
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
1.61 MB
Formato
Adobe PDF
|
1.61 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.