A proper evaluation of the uncertainty associated to the quantification of micropollutants in the environment, like Polycyclic Aromatic Hydrocarbons (PAHs), is crucial for the reliability of the measurement results. The present work describes a comparison between the uncertainty evaluation carried out according to the GUM uncertainty framework and the Monte Carlo (MC) method. This comparison was carried out starting from real data sets obtained from the quantification of benzo[a]pyrene (BaP), spiked on filters commonly used for airborne particulate matter sampling. BaP was chosen as target analyte as it is listed in the current European legislation as marker of the carcinogenic risk for the whole class of PAHs. MC method, being useful for nonlinear models and when the resulting output distribution for the measurand is non-symmetric, can particularly fit the cases in which the results of intrinsically positive quantities are very small and the lower limit of a desired coverage interval, obtained according to the GUM uncertainty framework, can be dramatically close to zero, if not even negative. In the case under study, it was observed that the two approaches for the uncertainty evaluation provide different results for BaP masses in samples containing different masses of the analyte, MC method giving larger coverage intervals. In addition, in cases of analyte masses close to zero, the GUM uncertainty framework would give even negative lower limit of uncertainty coverage interval for the measurand, an unphysical result which is avoided when using MC method. MC simulations, indeed, can be configured in a way that only positive values are generated thus obtaining a coverage interval for the measurand that is always positive.
Uncertainty evaluation for the quantification of low masses of benzo[a]pyrene: Comparison between the Law of Propagation of Uncertainty and the Monte Carlo method / Sega, Michela; Pennecchi, FRANCESCA ROMANA; Rinaldi, Sarah; Rolle, Francesca. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - 920:(2016), pp. 10-17. [10.1016/j.aca.2016.03.032]
Uncertainty evaluation for the quantification of low masses of benzo[a]pyrene: Comparison between the Law of Propagation of Uncertainty and the Monte Carlo method
	
	
	
		
		
		
		
		
	
	
	
	
	
	
	
	
		
		
		
		
		
			
			
			
		
		
		
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
						
							
							
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
			
			
				
				
					
					
					
					
						
							
						
						
					
				
				
				
				
				
				
				
				
				
				
				
			
			
		
		
		
		
	
SEGA, MICHELA
;PENNECCHI, FRANCESCA ROMANA;Rolle, Francesca
	
		
		
	
			2016
Abstract
A proper evaluation of the uncertainty associated to the quantification of micropollutants in the environment, like Polycyclic Aromatic Hydrocarbons (PAHs), is crucial for the reliability of the measurement results. The present work describes a comparison between the uncertainty evaluation carried out according to the GUM uncertainty framework and the Monte Carlo (MC) method. This comparison was carried out starting from real data sets obtained from the quantification of benzo[a]pyrene (BaP), spiked on filters commonly used for airborne particulate matter sampling. BaP was chosen as target analyte as it is listed in the current European legislation as marker of the carcinogenic risk for the whole class of PAHs. MC method, being useful for nonlinear models and when the resulting output distribution for the measurand is non-symmetric, can particularly fit the cases in which the results of intrinsically positive quantities are very small and the lower limit of a desired coverage interval, obtained according to the GUM uncertainty framework, can be dramatically close to zero, if not even negative. In the case under study, it was observed that the two approaches for the uncertainty evaluation provide different results for BaP masses in samples containing different masses of the analyte, MC method giving larger coverage intervals. In addition, in cases of analyte masses close to zero, the GUM uncertainty framework would give even negative lower limit of uncertainty coverage interval for the measurand, an unphysical result which is avoided when using MC method. MC simulations, indeed, can be configured in a way that only positive values are generated thus obtaining a coverage interval for the measurand that is always positive.| File | Dimensione | Formato | |
|---|---|---|---|
| 
									
										
										
										
										
											
												
												
												    
												
											
										
									
									
										
										
											Sega_ACA_2016_ 920.pdf
										
																				
									
										
											 non disponibili 
											Descrizione: Articolo principale
										 
									
									
									
										
											Tipologia:
											final published article (publisher’s version)
										 
									
									
									
									
										
											Licenza:
											
											
												Non Pubblico - Accesso privato/ristretto
												
												
												
											
										 
									
									
										Dimensione
										995.1 kB
									 
									
										Formato
										Adobe PDF
									 
										
										
								 | 
								995.1 kB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
| 
									
										
										
										
										
											
												
												
												    
												
											
										
									
									
										
										
											Accepted_Sega_ACA_2016_ 920.pdf
										
																				
									
										
											 accesso aperto 
											Descrizione: Articolo principale
										 
									
									
									
										
											Tipologia:
											accepted manuscript (author’s post-print)
										 
									
									
									
									
										
											Licenza:
											
											
												Creative Commons
												
												
													
													
													
												
												
											
										 
									
									
										Dimensione
										709.86 kB
									 
									
										Formato
										Adobe PDF
									 
										
										
								 | 
								709.86 kB | Adobe PDF | Visualizza/Apri | 
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.