KEY COMPARISON We report the results of the international comparison of low-frequency ac voltage ratio: CCEM-K7. The participants made measurements of a unique travelling standard: an inductive voltage divider which provided the 20 ac voltage ratios chosen for the comparison. The nominal ratios chosen were: 0.1 to 0.9, 0.01 and 1/11 to 10/11. Each of the 17 participants measured the in-phase and quadrature components of all 20 ratios at a frequency of 1 kHz, and 7 laboratories made additional, optional, measurements at a frequency of 55 Hz. The report consists of two separate parts: the first part describes the comparison and provides detailed uncertainty budgets for each participant; the second part describes the method used to analyse the results, gives the results of the comparison and tabulates the raw data provided by each participant. Main text. To reach the main text of this paper, click on Final Report (a zip file containing the report as two pdf files: Part 1 and Part 2). Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Key comparison CCEM-K7: AC voltage ratio / Robinson, I; Belliss, J; Bryant, S; Sánchez, A; Álvarez, J; Schweiger, K; Díaz, C; Neira, M; Callegaro, Luca; Duk Lee, R; Blanc, I; Overney, F; He, X. B.; Ding, C; Qian, Z. T.; Waltrip, B; Small, G; Fiander, J; Coogan, P; Johnson, H. L.; Nakamura, Y; Dierikx, E; Saxena, A. K.; Saleem, M; Wood, B; Ramm, G; Eklund, G; Turhan, E; Semenov, Y.. - In: METROLOGIA. - ISSN 1681-7575. - 49:(2012), pp. 01007-01007. [doi:10.1088/0026-1394/49/1A/01007]

Key comparison CCEM-K7: AC voltage ratio

CALLEGARO, LUCA;
2012

Abstract

KEY COMPARISON We report the results of the international comparison of low-frequency ac voltage ratio: CCEM-K7. The participants made measurements of a unique travelling standard: an inductive voltage divider which provided the 20 ac voltage ratios chosen for the comparison. The nominal ratios chosen were: 0.1 to 0.9, 0.01 and 1/11 to 10/11. Each of the 17 participants measured the in-phase and quadrature components of all 20 ratios at a frequency of 1 kHz, and 7 laboratories made additional, optional, measurements at a frequency of 55 Hz. The report consists of two separate parts: the first part describes the comparison and provides detailed uncertainty budgets for each participant; the second part describes the method used to analyse the results, gives the results of the comparison and tabulates the raw data provided by each participant. Main text. To reach the main text of this paper, click on Final Report (a zip file containing the report as two pdf files: Part 1 and Part 2). Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/32720
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact