Five Pt/Pd thermocouples, constructed and calibrated at IMGC at fixed points in the temperature range from 0 °C to the Ag point, were calibrated by comparison with the local primary standard radiation thermometer with the aim of replacing the presently used Pt/Pt–Rh alloy thermocouples as secondary reference standards up to 1500 °C. To fully exploit accuracy of Pt/Pd thermocouples, high-level calibration techniques need to be adopted. For this purpose, a new high-temperature three-zone furnace was arranged and characterized in order to obtain the best axial uniformity and a specially designed blackbody cavity was used as a transfer source for calibrating the thermocouples in the temperature range from 962 °C up to 1500 °C. At the end of the comparison measurements, additional calibrations at the Ag fixed point were made, in order to check the stability of the thermocouples’signals. A comparison between experimental results and the reference function is presented and an extrapolation of the fixed-point calibration data is analysed.

Facility for the calibration of Pt/Pd thermocouples in the temperature range from 960 °C to 1500 °C / Astrua, Milena; Battuello, Mauro; Girard, Ferruccio. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 17:(2006), pp. 2186-2190. [10.1088/0957-0233/17/8/018]

Facility for the calibration of Pt/Pd thermocouples in the temperature range from 960 °C to 1500 °C

ASTRUA, MILENA;BATTUELLO, MAURO;GIRARD, FERRUCCIO
2006

Abstract

Five Pt/Pd thermocouples, constructed and calibrated at IMGC at fixed points in the temperature range from 0 °C to the Ag point, were calibrated by comparison with the local primary standard radiation thermometer with the aim of replacing the presently used Pt/Pt–Rh alloy thermocouples as secondary reference standards up to 1500 °C. To fully exploit accuracy of Pt/Pd thermocouples, high-level calibration techniques need to be adopted. For this purpose, a new high-temperature three-zone furnace was arranged and characterized in order to obtain the best axial uniformity and a specially designed blackbody cavity was used as a transfer source for calibrating the thermocouples in the temperature range from 962 °C up to 1500 °C. At the end of the comparison measurements, additional calibrations at the Ag fixed point were made, in order to check the stability of the thermocouples’signals. A comparison between experimental results and the reference function is presented and an extrapolation of the fixed-point calibration data is analysed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/31470
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact