Transition-edge sensors (TESs) are very versatile superconducting devices used to detect radiation from gamma-rays to visible and submillimeter. The intrinsic capability to measure the energy of the absorbed photons with very high energy resolution and the related possibility to resolve the number of incident photons distinguish photon-number resolving (PNR) devices from any other photon detectors. PNR detectors are fundamental for the measurement of the photon-number distribution of singlephoton emitters and for the progress of quantum information technology and quantum metrology. By reducing the active area of TESs for visible-NIR light from typical values of 10-10 m2 toward 10-12 m2 and by increasing the TES operating temperature, we should be able to combine the high energy resolution permitted by very low heat capacity with fast response time. To support the future design and development of this new type of detector, in this work we compare experimental data with circuit simulation results based on the two-fluid theory.
Reduced active area in transition-edge sensors for visible-NIR photon detection: A comparison of experimental data and two-fluid model / Taralli, Emanuele; Lolli, L; Portesi, Chiara; Monticone, Eugenio; Rajteri, Mauro; Wang, T. S.; Chen, J. K.; Zhou, X.. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - 25:3(2015), p. 2200304.2200304. [10.1109/TASC.2014.2367469]
Reduced active area in transition-edge sensors for visible-NIR photon detection: A comparison of experimental data and two-fluid model
TARALLI, EMANUELE
;PORTESI, CHIARA;MONTICONE, EUGENIO;RAJTERI, MAURO;
2015
Abstract
Transition-edge sensors (TESs) are very versatile superconducting devices used to detect radiation from gamma-rays to visible and submillimeter. The intrinsic capability to measure the energy of the absorbed photons with very high energy resolution and the related possibility to resolve the number of incident photons distinguish photon-number resolving (PNR) devices from any other photon detectors. PNR detectors are fundamental for the measurement of the photon-number distribution of singlephoton emitters and for the progress of quantum information technology and quantum metrology. By reducing the active area of TESs for visible-NIR light from typical values of 10-10 m2 toward 10-12 m2 and by increasing the TES operating temperature, we should be able to combine the high energy resolution permitted by very low heat capacity with fast response time. To support the future design and development of this new type of detector, in this work we compare experimental data with circuit simulation results based on the two-fluid theory.File | Dimensione | Formato | |
---|---|---|---|
ASC14-Taralli-final_m.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
accepted manuscript (author’s post-print)
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
397.47 kB
Formato
Adobe PDF
|
397.47 kB | Adobe PDF | Visualizza/Apri |
taralli _ASC14_TES cina.pdf
non disponibili
Descrizione: Articolo principale
Tipologia:
final published article (publisher’s version)
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
354.14 kB
Formato
Adobe PDF
|
354.14 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.