Two types of international comparisons of femtosecond laser frequency combs have been performed in France and the USA. Five combs were involved in the comparisons. Three combs, of which two are transportable, employ nonlinear photonic crystal fiber (PCF) to obtain a wide spectrum covering a full optical octave. The other two are based on broadband femtosecond lasers and require no PCF. The comparisons were performed by counting the optical heterodyne beats between pairs of combs. The frequency agreement among three combs was at the subhertz level in the 563 THz part of the comb spectrum when the combs were referenced to a hydrogen maser. When the combs were referenced to an optical standard, the frequency agreement among four combs was much improved and found to be at the 10 19 level in the spectral range of 333–473 THz. The fact that this result is obtained by five independent measurement systems (combs) strengthens the conclusion that no systematic effects are present at this level.

International comparisons of femtosecond laser frequency combs RID B-3456-2009 / Ma, Ls; Bi, Zy; Bartels, A; Robertsson, L; Zucco, Massimo; Windeler, Rs; Wilpers, G; Oates, C; Hollberg, L; Diddams, Sa. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 54:2(2005), pp. 746-749. [10.1109/TIM.2005.843580]

International comparisons of femtosecond laser frequency combs RID B-3456-2009

ZUCCO, MASSIMO;
2005

Abstract

Two types of international comparisons of femtosecond laser frequency combs have been performed in France and the USA. Five combs were involved in the comparisons. Three combs, of which two are transportable, employ nonlinear photonic crystal fiber (PCF) to obtain a wide spectrum covering a full optical octave. The other two are based on broadband femtosecond lasers and require no PCF. The comparisons were performed by counting the optical heterodyne beats between pairs of combs. The frequency agreement among three combs was at the subhertz level in the 563 THz part of the comb spectrum when the combs were referenced to a hydrogen maser. When the combs were referenced to an optical standard, the frequency agreement among four combs was much improved and found to be at the 10 19 level in the spectral range of 333–473 THz. The fact that this result is obtained by five independent measurement systems (combs) strengthens the conclusion that no systematic effects are present at this level.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/29265
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact