Ultrasound (US) irradiation and microwave (MW) heating of aqueous solutions have shown synergetic effects and can foster advanced processing when applied simultaneously or sequentially [1]. Here we try to characterize in more detail the acoustic cavitation phenomena taking place in such setups. Our aims comprise a better understanding of the physical effects, but also a suitable way to monitor cavitation activity of the system. To this end, we conduct several types of experiments where acoustic emissions of sonicated and heated water are recorded and analyzed. Partly the bubbles are observed in parallel with high-speed imaging (see Fig. 1). Results show that essentially two different states of cavitation can appear, depending on state and history of the system parameters: (i) a "gassy" cavitation state where large and weakly collapsing bubbles occur with acoustic emissions remaining on a lower level; and (ii) a "hard" cavitation regime with smaller and stronger collapsing bubbles where acoustic emissions are on a high level. The regimes are similar to the non-degassed and degassed state of cavitating liquid that are encountered, for instance, during pre-treatment of water by heating and ultrasonic degassing in the context of cleaning applications [2]. Here, however, the microwave heating plays a special role that is not yet fully understood. In particular, turning MW on and off during sonication can alternately switch between gassy (MW on) and hard (MW off) cavitation regimes, even without significant temperature (i.e. air saturation) changes of the liquid. Our results indicate (a) that acoustic cavitation emissions into air can be used for cavitation assessment, (b) that simultaneous application of US/MW can compromise sonochemical activity by switching to a soft, gassy cavitation regime, (iii) that alternating or pulsed US/MW application might be a favorable strategy for improvement of synergy of both energy sources, and (iv) that the microscopic degassing and nucleating effects of MW in connection with US still need more exploration.

Ultrasonic cavitation under microwave irradiation: bubbles and acoustic emissions / Mettin, Robert; Stephens, Dwayne; Cravotto3, Giancarlo; Martina, Katia; Troia, Adriano. - (2024). (Intervento presentato al convegno ESS 18 tenutosi a Leuven nel 27. - 31.05.2024).

Ultrasonic cavitation under microwave irradiation: bubbles and acoustic emissions

Adriano Troia
2024

Abstract

Ultrasound (US) irradiation and microwave (MW) heating of aqueous solutions have shown synergetic effects and can foster advanced processing when applied simultaneously or sequentially [1]. Here we try to characterize in more detail the acoustic cavitation phenomena taking place in such setups. Our aims comprise a better understanding of the physical effects, but also a suitable way to monitor cavitation activity of the system. To this end, we conduct several types of experiments where acoustic emissions of sonicated and heated water are recorded and analyzed. Partly the bubbles are observed in parallel with high-speed imaging (see Fig. 1). Results show that essentially two different states of cavitation can appear, depending on state and history of the system parameters: (i) a "gassy" cavitation state where large and weakly collapsing bubbles occur with acoustic emissions remaining on a lower level; and (ii) a "hard" cavitation regime with smaller and stronger collapsing bubbles where acoustic emissions are on a high level. The regimes are similar to the non-degassed and degassed state of cavitating liquid that are encountered, for instance, during pre-treatment of water by heating and ultrasonic degassing in the context of cleaning applications [2]. Here, however, the microwave heating plays a special role that is not yet fully understood. In particular, turning MW on and off during sonication can alternately switch between gassy (MW on) and hard (MW off) cavitation regimes, even without significant temperature (i.e. air saturation) changes of the liquid. Our results indicate (a) that acoustic cavitation emissions into air can be used for cavitation assessment, (b) that simultaneous application of US/MW can compromise sonochemical activity by switching to a soft, gassy cavitation regime, (iii) that alternating or pulsed US/MW application might be a favorable strategy for improvement of synergy of both energy sources, and (iv) that the microscopic degassing and nucleating effects of MW in connection with US still need more exploration.
2024
ESS 18
27. - 31.05.2024
Leuven
open
File in questo prodotto:
File Dimensione Formato  
ESS18_R.Mettin_KM.docx

accesso aperto

Tipologia: abstract
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 427.9 kB
Formato Microsoft Word XML
427.9 kB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/82182
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact