The revision of the International System of Units (SI) allows, since May 2019, the practical realization of the electrical resistance unit, the ohm (Ω), directly from the Quantum Hall Effect (QHE), which effectively becomes its mise en pratique. This technical report illustrates the comparison measurements, carried out between 11th November and 3rd December 2020 as a part of the measurement campaign n° 128, aimed to characterize the Cryogenic Current Comparator (CCC) bridge and to find the best definition of the measurement circuit to be implemented for the traceability transfer starting from the QHE.

L’avvenuta revisione del Sistema Internazionale di unità di misura (SI) permette, a partire da maggio 2019, la realizzazione pratica dell’unità di resistenza elettrica, l’ohm (Ω), direttamente dall’effetto Hall quantistico (Quantum Hall Effect, QHE), che ne diventa di fatto la mise en pratique. Il presente rapporto tecnico illustra le misure di confronto, eseguite tra il 11 novembre al 3 dicembre 2020 nell’ambito della campagna di misura n° 128, finalizzate alla caratterizzazione del ponte a comparatore criogenico di correnti (Cryogenic Current Comparator, CCC) e alla miglior definizione del circuito di misura da realizzare per il trasferimento della riferibilità a partire dal QHE.

Confronti di resistenza con il ponte a comparatore criogenico di correnti Magnicon / Callegaro, L.; Cassiago, C.; D'Elia, V.; Gasparotto, E.. - (2021), pp. 1-39.

Confronti di resistenza con il ponte a comparatore criogenico di correnti Magnicon

Callegaro, L.;Cassiago, C.
;
D'Elia, V.;Gasparotto, E.
2021

Abstract

The revision of the International System of Units (SI) allows, since May 2019, the practical realization of the electrical resistance unit, the ohm (Ω), directly from the Quantum Hall Effect (QHE), which effectively becomes its mise en pratique. This technical report illustrates the comparison measurements, carried out between 11th November and 3rd December 2020 as a part of the measurement campaign n° 128, aimed to characterize the Cryogenic Current Comparator (CCC) bridge and to find the best definition of the measurement circuit to be implemented for the traceability transfer starting from the QHE.
2021
08/2021
reserved
File in questo prodotto:
File Dimensione Formato  
RT-2021-08.pdf

non disponibili

Tipologia: final published article (publisher’s version)
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.45 MB
Formato Adobe PDF
3.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11696/73694
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact